Add:Room506、507、88 Nanxijiang Road,Wuzhong District, Suzhou City ,China
Tel:+86-512-66267500
Fax:+86-512-66262500
Mobile:+86-15995883441
LFC(Low Fouling Composite)membrane applicable to industrial waste water urban sewerage depth desalting treatment. LFC3-LD the charge on the surface of the membrane is neutral and the introduction of hydrophilic functional groups, almost no effect on the adsorption of surfactant or other charger substances .LFC3-LD on the basis of electrical neutrality and net technology) reducing biological pollution.
Feature1.LFC(Low Fouling Composite)membrane ,the composite membrane has the characteristics of low pressure high flux and high desalination rate. It is also hydrophilic and electrically neutral. Compared with traditional reverse osmosis membrane elements with negative charge. LFC series the surface of the anti-pollution reverse osmosis membrane is electrically neutral of positively charged.
2.LFC uses different charge surfactants to contact the traditional aromatic polyamide composite film with negative charge respectively, it can be found that the electroneutral reverse osmosis membrane exhibits a stable water flux in different surfactants.
3.LFC series of 8-inch products featured LFC3-LD 4mil products has LFC3-LD4040 can meet different deeds.
Model |
LFC3-LD |
LFC3-LD-4040 |
|
type |
size |
8-inch |
4-inch |
membrane material |
(Aromatic polyamide composite material |
||
Membrane active area (m2) |
37.2 |
7.4 |
|
Thickness of inlet net |
34(LD技术) |
||
function |
Average desalinization rate (%) |
99.7 |
|
Mini desalinization (%) |
99.5 |
||
Water yield (m3/d) |
41.6 |
8.0 |
|
Testing conditions |
Solution concentration (mg/L) |
1500 |
|
Operating pressure (MPa) |
1.55 |
||
Test temperature (℃) |
25 |
||
Single component water recovery(%) |
15 |
||
The test liquid PH |
6.5-7.0 |
||
Conditions of use |
Maximum operating pressure (MPa) |
4.14 |
|
Maximum inflow (m3/h) |
17.0 |
3.6 |
|
Maximum inlet temperature(℃) |
45 |
||
Inlet PH range |
2-10 |
||
Cleaning PH range |
1-12 |
||
Maximum turbidity of water, NTU |
1.0 |
||
Largest water SDI |
<5 |
||
Maximum water residual chlorine |
0 |
||
Minimum concentration and |
5:1 |
||
Single film biggest pressure drop(MPa) |
0.07 |